ONLINE UPS
LEVELUPS SERIES 10 - 1000 kVA
 
10 - 1000 kVA
 
10 - 30 kVA
 
 
HIGHLIGHTS
 
• True Three Level Rectifier and Inverter Technology
• Ultra High Energy Effiency
• Full Rated Power Factor kW=kVA

DATA CENTER

MEDICAL

INDUSTRY

TRANSPORT

EMERGENCY
VFI TYPE VI TYPE VFD TYPE 9 6 % Efficiency 9 7 % Efficiency UPS ThreeLEVEL PF=0.9 PF=1.0 Service LUGLAY
tabmenu
INNOVATIVE 3 LEVEL TECHNOLOGY
LevelUps series with Innovative 3 Level Technology is a true on-line double conversion, three-phase UPS system that provides one of the highest level energy efficiencies in the industry.




HIGH EFFICIENCY & LOW TOTAL COST OF OWNERSHIP
Three level inverter & rectifier design LevelUps series brings the newest power conversion technology and delivers efficiency up to 96% at 50-75% load operation which is the most common operating range.

Less energy consumption to supply the loads thanks to high efficiency up to 96%.
  • Reduced energy loss.
  • Reduced electricity usage and air conditioning requirements.
  • Reduction in operating cost of UPS.
High Efficiency & Low Total Cost of Ownership
  • Less energy consumption to supply the loads thanks to high efficiency up to 96%.
  • Reduced energy loss.
  • Reduced electricity usage and air conditioning requirements.
  • Reduction in operating cost of UPS.
  • IGBT based power factor correction technology provides input power factor close to 1 (≥ 0,99). The high input power leads to reduced electricity pay-out, minimizes cable, switchboard, fuse and generator requirements, thus reducing investment cost.
  • Low input current total harmonic distortion (THDi) less than 3% helps to avoid the disturbance and expensive harmonic filters.
  • Small footprint and easy maintenance.
High Output Power Factor 1
  • Output power factor of 1 (kVA=kW) rate provides up to 25% more active power than a traditional UPS.
  • Suitable for modern power supply application with unit or capacitive power factor (e.g. new servers generation).
  • No reduction in active power from 0,9 leading to 0,9 lagging.
Maximum Availability
  • Parallel configuration up to 8 units per redundancy (N+1) and power increase.
  • Loop connection helps the UPS system to continue the operation when the connection cable is inturrupted.


Standard Electrical Features
  • Dual Input
  • Common Battery
  • Backfeed Protection
  • Cold Start (Optional)
  • Advanced Battery Management
  • Short Circuit and Overload Protection
  • Parallel Ready
  • Redundant Power Supply
  • Power Walk-in for Progressive Rectifier Start-up when the
  • Mains is Restored.
  • Battery Temperature Sensor
  • Static and Manual Bypass Operation
Advanced Communication Features
  • 500 Real Time Event Log with Detailed Parameters
  • User Friendly Multilingual 320x240 Graphic Display Provides
  • Operation Information
  • Monitoring and Shutdown Software
  • RS232 Serial and RS485 Ports
  • Modbus RTU (Optional)
  • 2 Communication Slots
  • Remote Emergency Power Off (Optional)
  • Remote Display Panel (Optional)
  • Dry Contact (Optional)
  • SNMP (Optional)
  • ProfiBUS (Optional)
Flexibility
  • Temperature sensor for external battery cabinets for extended runtimes.
  • External battery cabinets for different sizes of batteries to provide extended runtimes.
  • Different sizes of 10-40kVA cabinets for larger capacity of internal batteries when long autonomy times are required.
  • 3/1 Phase version is available for 10-30kVA power ratings Frequency converter mode.
  • Isolation transformers to vary neutral connectivity in the event of separate power sources or for galvanic isolation between input and output.
  • Compatible version with EN 50171 for supplying power to emergency lighting systems.







Catalogues
  LevelUps Serisi 10 - 1000 kVA
    
 
TR
 
EN




Kullanma Kılavuzları
  LevelUps Serisi 10 - 20 kVA Kullanma Kılavuzu
    
 
TR
 
EN
  LevelUps Serisi 30 - 40 kVA Kullanma Kılavuzu
    
 
TR
 
EN
  LevelUps Serisi 60 - 80 kVA Kullanma Kılavuzu
    
 
TR
 
EN
  LevelUps Serisi 100 - 120 kVA Kullanma Kılavuzu
    
 
TR
 
EN
  LevelUps Serisi 160 - 200 - 250 kVA Kullanma Kılavuzu
    
 
TR
 
EN
  LevelUps Serisi 300 - 400 - 500 kVA Kullanma Kılavuzu
    
 
TR
 
EN
INNOVATIVE 3 LEVEL TECHNOLOGY
LevelUps series with Innovative 3 Level Technology is a true on-line double conversion, three-phase UPS system that provides one of the highest level energy efficiencies in the industry.



• 

HIGH EFFICIENCY & LOW TOTAL COST OF OWNERSHIP
Three level inverter & rectifier design LevelUps series brings the newest power conversion technology and delivers efficiency up to 96% at 50-75% load operation which is the most common operating range.

Less energy consumption to supply the loads thanks to high efficiency up to 96%.
  • Reduced energy loss.
  • Reduced electricity usage and air conditioning requirements.
  • Reduction in operating cost of UPS.
High Efficiency & Low Total Cost of Ownership
High Output Power Factor 1
Maximum Availability
  • Parallel configuration up to 8 units per redundancy (N+1) and power increase.
  • Loop connection helps the UPS system to continue the operation when the connection cable is inturrupted.


Standard Electrical Features
  • Dual Input
  • Common Battery
  • Backfeed Protection
  • Cold Start (Optional)
  • Advanced Battery Management
  • Short Circuit and Overload Protection
  • Parallel Ready
  • Redundant Power Supply
  • Power Walk-in for Progressive Rectifier Start-up when the
  • Mains is Restored.
  • Battery Temperature Sensor
  • Static and Manual Bypass Operation
Advanced Communication Features
  • 500 Real Time Event Log with Detailed Parameters
  • User Friendly Multilingual 320x240 Graphic Display Provides
  • Operation Information
  • Monitoring and Shutdown Software
  • RS232 Serial and RS485 Ports
  • Modbus RTU (Optional)
  • 2 Communication Slots
  • Remote Emergency Power Off (Optional)
  • Remote Display Panel (Optional)
  • Dry Contact (Optional)
  • SNMP (Optional)
  • ProfiBUS (Optional)
Flexibility
  • Temperature sensor for external battery cabinets for extended runtimes.
  • External battery cabinets for different sizes of batteries to provide extended runtimes.
  • Different sizes of 10-40kVA cabinets for larger capacity of internal batteries when long autonomy times are required.
  • 3/1 Phase version is available for 10-30kVA power ratings Frequency converter mode.
  • Isolation transformers to vary neutral connectivity in the event of separate power sources or for galvanic isolation between input and output.
  • Compatible version with EN 50171 for supplying power to emergency lighting systems.







Brochure
  LevelUps Series 10 - 1000 kVA
    
 
TR
 
EN
  LevelUps Series 10 - 1000 kVA
    
 
TR
 
EN
  LevelUps Series 10 - 1000 kVA
    
 
TR
 
EN
  LevelUps Series 10 - 1000 kVA
    
 
TR
 
EN
  LevelUps Series 10 - 1000 kVA
    
 
TR
 
EN




User Manuals
  LevelUps Serisi 10 - 20 kVA Kullanma Kılavuzu
    
 
TR
 
EN
  LevelUps Serisi 30 - 40 kVA Kullanma Kılavuzu
    
 
TR
 
EN
  LevelUps Serisi 60 - 80 kVA Kullanma Kılavuzu
    
 
TR
 
EN
  LevelUps Serisi 100 - 120 kVA Kullanma Kılavuzu
    
 
TR
 
EN
  LevelUps Serisi 160 - 200 - 250 kVA Kullanma Kılavuzu
    
 
TR
 
EN
  LevelUps Serisi 300 - 400 - 500 kVA Kullanma Kılavuzu
    
 
TR
 
EN
 
RELATED ACCESSORIES



ACCESSORIES
MakNET SNMP Card

ACCESSORIES
R335 Dry Contact (Relay) Card

ACCESSORIES
Remote Panel

ACCESSORIES
MakNET UPS Management Software

ACCESSORIES
ModBUS Card

ACCESSORIES
Rail Kit

ACCESSORIES
Service Bypass Panel

ACCESSORIES
Static Transfer Switch

ACCESSORIES
Battery Cabinets

ACCESSORIES
Battery Management System
 
APPLICATION & SECTORS